Glossary

The terms that come up in every building envelope project – from glass types, through curtain wall systems, to the design and construction stages – briefly explained, with what each one means for the developer and project manager.

Glass

Monolithic glass

Single glazing

A single pane of glass, with no interlayer and no cavity. Its thermal and acoustic insulation is low, so it is rarely the main glazing of a conditioned building. It appears mostly as a component of laminated or insulating glass, or in unconditioned elements such as railings and canopies.

Laminated glass

Triplex

Two or more panes bonded by a clear interlayer (PVB or SGP). When it breaks, the fragments stay on the interlayer and the pane does not fall – so it is required wherever breakage could endanger people: railings, overhead glazing, and high facades. The interlayer also improves acoustic insulation.

Insulating glass unit (IGU)

Double glazing

Two (or three) panes separated by a spacer and sealed around the edge, with dry air or argon gas between them. It is the standard glazing of curtain walls, because the cavity greatly reduces heat flow. A Low-E coating is usually added on one of the inner surfaces.

Laminated insulating glass

An insulating glass unit in which one or both panes are laminated. The same unit then gives thermal insulation, safety on breakage and better acoustics. Which pane is laminated – outer, inner or both – follows from the building height, the code requirements and the noise around the site.

Curved glass

Bent glass

Glass heat-formed to a given radius, as a single pane, laminated glass or an insulating unit. Radius, thickness and heat treatment all have production limits, and lead times are longer than for flat glass. It is worth checking with suppliers at design stage that the geometry can be produced, and approving the optical distortion on a sample.

Clear glass

Clear float glass

Ordinary float glass. Its raw material naturally contains iron, which gives it a slight green tint, visible at the edges and in thick or multi-layer glass. For most facades it is enough; where the tint conflicts with the architectural intent, low-iron glass is used instead.

Low-iron glass

Extra clear

Glass made with reduced iron content, so it is almost colorless and lets more light through. It costs more than ordinary clear glass, so it pays to decide early where it really matters – shopfronts, railings, thick glass – rather than across the whole facade.

Annealed glass

Float glass

Glass that has not been tempered or heat treated. It breaks into large, sharp shards, so on its own it is not safety glass. Its advantages: it is perfectly flat and carries no risk of spontaneous breakage, which makes it a common component of laminated glass.

Heat-strengthened glass

HS glass

Glass given a milder heat treatment than full tempering, making it about twice as strong as annealed glass. It breaks into large pieces that stay in place within a laminate, and its risk of spontaneous breakage is negligible. On high facades it is often chosen instead of fully tempered glass.

Tempered glass

Toughened glass

Glass heated in a furnace to a high temperature and quickly cooled, making it four to five times stronger than annealed glass. It breaks into small, less dangerous granules. The drawback is a risk of spontaneous breakage, so facades usually call for a heat soak test.

Spontaneous breakage

Nickel sulfide breakage

Tempered glass breaking with no impact or load, sometimes years after installation. The main cause is a tiny nickel sulfide (NiS) inclusion trapped in the glass that slowly expands. On a high facade each such break is a costly safety and maintenance event, so protection against it is set in the specification and the tender.

Heat soak test (HST)

HST

An extra heating cycle for tempered glass at the factory, so panes with nickel sulfide inclusions break there rather than on the building. It greatly reduces the risk of spontaneous breakage but does not remove it. It belongs in the tender specification, with records required for every batch.

Low-E coating

Low-emissivity coating

A very thin metallic coating on one of the glass surfaces that reduces heat flow and filters part of the solar radiation. Makers label it with two numbers, for example 70/37: the percentage of light and of solar energy that passes. Choosing a coating balances daylight, heat, color and reflection – and it is worth seeing a real sample before deciding.

See also: Visible light transmittance (VLT)

Visible light transmittance (VLT)

Light transmittance

The percentage of visible light that passes through the glass. A high VLT means a brighter space and a clearer view out. Coatings, tints, ceramic frit and the number of glass layers lower it.

When choosing: a VLT that is too low darkens the space and increases the use of lighting, and at night also strengthens reflections from inside. A very high VLT on a sun-exposed facade increases glare. The value is therefore chosen together with the shading, and the glass is approved on a sample.

See also: Low-E coating, Solar heat gain coefficient (SHGC)

PVB and SGP interlayers

The two kinds of interlayer that bond laminated glass. PVB is flexible, common and cheaper, and improves acoustic insulation. SGP is far stiffer and stronger: after breakage the pane keeps its shape and stays in place, and it copes better with exposed edges. For large panes, railings and overhead glazing it is often chosen despite the price.

See also: Cantilevered glass balustrade

Ceramic frit

Fritted glass

Ceramic paint printed on the glass and fused into it during tempering, so it does not wear off. It is used for shading, privacy, concealing the spandrel and bird protection, and as an architectural language – dots, stripes or a full pattern. It should be approved on a sample and a mock-up, because it looks different in changing light.

Facade systems

Curtain wall

Glazed facade

An aluminum and glass facade that does not carry the building: it hangs on the structure, carries its own weight and the wind loads, and transfers them to the floor slabs. A curtain wall is designed and made as a complete system, so its quality is set in design, specification and contractor selection. The two main methods are stick and unitized.

Stick curtain wall

Stick system

A curtain wall built on site piece by piece: aluminum mullions and transoms are fixed to the building first, then glazed. It is flexible, suits complex geometry and low- to mid-rise buildings, and needs little lead time or storage. On the other hand, most of the work happens at height and in site conditions, so quality supervision on site is critical.

Unitized curtain wall

Unitised system

A curtain wall made in the factory as complete units – frame, glass and seals – that arrive on site ready to install. Each unit is lifted and hung on anchors at the slab edge, and installation is done from inside the floor, with no external scaffolding. It is fast and gives factory quality, so it suits towers and large repetitive facades in particular. It needs an early design freeze, a longer production lead time, and planned storage and logistics.

Mullion and transom

Mullion / Transom

The two profiles that make up the curtain wall grid. The mullion is the vertical profile. It hangs on the anchors on the outer face of the floor slabs, carries the weight of the facade and the wind loads, and transfers them to the structure. The transom is the horizontal profile between the mullions. It carries the weight of the glass and divides the facade into bays. The mullion spacing, the storey height and the wind loads set the mullion depth, and with it the facade's look from inside, the amount of aluminum and the cost. In a unitized curtain wall the mullion is split into two halves, one in each unit, as is the transom where units of adjacent floors meet.

Pressure equalization and drainage

Drained and pressure-equalized system

A curtain wall is designed on the assumption that some water will get past the outer seal. The profile therefore has a chamber that collects this water and drains it out through weep holes at the bottom of each bay.

Pressure equalization: the chamber is vented to the outside air, so the pressure inside it equals the pressure outside. When wind presses on the facade there is no pressure difference driving water inward, and it runs down to the drainage. Airtightness is provided by the inner seal, which is protected from direct rain.

In the specification and on site: weep hole positions, end dams in the profiles and the sealing of joints are set in the shop drawings and tested on the PMU. On site, inspectors check that weep holes have not been blocked with silicone or dirt, a common cause of water penetration.

See also: PMU, Mullion and transom

Anchor

Bracket

The component that connects the facade to the structure and transfers the facade's weight and wind loads to it. The anchor allows adjustment in three axes, to absorb the deviations and movements of the structure.

In a stick system the anchor is fixed to the outer face of the slab after it is cast, and the mullion is bolted to it on site through slotted holes that allow adjustment. Usually each mullion is fixed at one point, where it carries its weight, and connected at the other end with a joint that allows movement.

In a unitized system the anchor is prepared in advance, often fixed into a channel cast into the slab. The unit is lifted and hooked onto the anchor, then adjusted with levelling bolts from inside the floor. Where cast-in channels are used, the anchor positions are set before the slabs are poured, so coordination with the engineer and the main contractor has to happen much earlier than with a stick system.

Structural glazing

SSG

Glazing in which the glass is bonded to the frame with structural silicone, with no pressure plate or cover cap outside. From outside it reads as a continuous glass surface with only a narrow silicone joint between panes. The bond is part of the load-bearing system, so it needs a precise specification, controlled fabrication and silicone testing.

Pressure plate glazing

Captured glazing

Glazing in which the glass is clamped to the frame by an outer pressure plate screwed in place and covered by an aluminum cap. It is the simplest and most common method, and the caps draw visible lines on the facade. The depth and shape of the cap can be used as part of the architectural language.

Semi-structural curtain wall

A curtain wall combining both methods: on some edges the glass is bonded with structural silicone, on others it is held by a pressure plate and cap. The result is lines in one direction only – vertical or horizontal – or projecting profiles that shape the facade.

Thermal break

Polyamide break

A plastic strip (usually polyamide) separating the outer part of an aluminum profile from its inner part. Aluminum conducts heat well, and the break stops it from carrying heat and cold through the facade – reducing energy use and the risk of condensation inside.

See also: Thermal bridge

Thermal bridge

Cold bridge

A point or line in the envelope where heat passes far more easily than through the rest of the facade. Examples: an aluminum profile without a thermal break, a slab edge or concrete column left uninsulated, and an anchor or metal connection that crosses the insulation layer. In winter the inside surface there is colder than around it, and that is where condensation and mold form. In summer heat comes in through it. Because of thermal bridges, the facade's actual insulation is lower than the value of the glass or the insulation alone. They are therefore identified at design stage and dealt with in the details: thermal breaks in the profiles, continuous insulation and thermal separation at the anchors.

See also: Thermal break

Spandrel

Spandrel panel

The opaque zone of a curtain wall in front of the slab edge and the ceiling void, concealing structure and services. Behind it are insulation and the fire stop between floors. It can be made of painted or printed glass, metal or other cladding; the choice affects the facade look, the insulation and the cost.

Double-skin facade

Double skin

A facade of two glazing layers with a cavity between them. The cavity can hold shading protected from wind and dust, and acts as a thermal and acoustic buffer. It may be ventilated or closed, and each changes maintenance, performance and cost – so the decision is made early in design.

Closed cavity facade (CCF)

CCF

A double-skin facade whose cavity is sealed, with dry, filtered air supplied to it to prevent condensation and dust. Shading blinds are usually installed in the cavity, where they stay clean and protected. The result is a relatively slim facade with high thermal performance, but it needs an air supply system and maintenance planning for the life of the building.

BIPV

Building-integrated photovoltaics

Photovoltaic cells built into the facade itself – in the glass, the spandrel or the cladding – that generate electricity. They replace regular facade material, so they affect the look, wiring, maintenance and green building compliance. To work, BIPV has to enter the design early, together with a feasibility review.

Dry cladding

Mechanically fixed cladding

A cladding method in which panels or tiles are fixed to an aluminum or steel secondary structure with mechanical connections such as clips, screws, hangers or rails, rather than bonded to the wall with mortar or adhesive. A cavity remains between the cladding and the wall, usually serving as a ventilated facade and allowing insulation to be added on the outside.

See also: Ventilated facade, Aluminium composite panels (ACP), HPL panels, Porcelain panel cladding, Cassette cladding

Cassette cladding

Panel cladding

Cladding of aluminum panels folded into trays and hung on a secondary structure over the building wall. A ventilated gap remains between panels and wall, protecting the insulation and the wall. It allows a wide range of colors, sizes and perforations.

Aluminium composite panels (ACP)

Alucobond

A cladding panel of two thin aluminum skins with a core between them. Alucobond is a common trade name for this type. The core decides how the panel behaves in fire: a polyethylene core is combustible, and there are also fire-retardant and non-combustible cores. In tall buildings the core type follows the fire requirements that apply to the project, so it is written into the specification rather than left to the contractor.

HPL panels

High Pressure Laminate

Panels made of layers of resin-impregnated paper pressed under high pressure and heat, with a decorative top layer. Facades use compact HPL panels for exterior use, fixed on a secondary structure as a ventilated facade. The panels come in a standard and a fire-retardant grade, chosen according to the project's fire requirements. The panel expands and contracts with heat and moisture, so the fixings must allow movement. The color and its UV resistance should be confirmed in the specification.

Porcelain panel cladding

Porcelain tile cladding

Porcelain tiles and panels, often in large formats, installed as dry cladding: on an aluminum secondary structure, with clips, kerfs in the back of the tile or bonding to a frame. Dry cladding leaves a ventilated cavity behind the tiles and avoids the risks of wet-fixing to the wall. Tile weight and size determine the secondary structure. On tall buildings retention measures are also specified, such as a mesh on the back of the tile or safety clips, so that a cracked tile cannot fall. The joint layout is set together with the architect.

Ventilated facade

Rainscreen

Cladding installed on a secondary structure at a distance from the wall, leaving an air cavity between them that is open at the bottom and the top.

Stack effect: air enters the cavity at the bottom, is warmed by the sun striking the cladding, rises and leaves at the top. This natural flow carries away part of the heat before it reaches the wall, and dries out moisture and water that got in through the joints. The cladding keeps the rain off, and the cavity lets the wall and the insulation stay dry.

Insulation outside: a ventilated facade allows the thermal insulation to move to the outside of the wall, in the cavity behind the cladding. The insulation runs continuously over slab edges and columns, avoiding the thermal bridges created by insulating from inside. The wall's mass stays on the inside and steadies the temperature, and no floor area is lost to insulation thickness.

Fire: the same stack effect can carry fire and smoke along the cavity. Cavity fire barriers are therefore required between floors and around openings, and the cladding and insulation materials are chosen to meet the fire requirements that apply to the project.

Tilt and turn window

Dreh-Kipp

A window that opens inward in two modes: tilted for ventilation, or turned for full opening and cleaning. The hardware sets the maximum sash size and weight. When tilted, acoustic insulation drops considerably, which matters near busy roads. The name in Israel comes from the German Dreh-Kipp: Dreh means turn, Kipp means tilt.

Lift and slide system

Hebe-Schiebe

A heavy sliding door whose sash is lifted off its seals while sliding and lowered onto them when closed. This allows large openings with good weather-tightness. The threshold, drainage and floor recess details must be coordinated in advance with the main contractor. The system is also known by its German name, Hebe-Schiebe: Hebe means lift, Schiebe means slide.

Cantilevered glass balustrade

Frameless glass railing

A glass balustrade without posts, in which each glass panel is clamped only at its base, in a continuous aluminum channel anchored to the slab. The glass rises like a cantilever and on its own carries the load of people leaning on it.

A cantilevered balustrade requires laminated glass with an SGP interlayer. The stiff interlayer holds the panel's shape, so even if it breaks it stays standing in place. The glass thickness follows the loads, the height and the exposure. Where required, a handrail or a top profile linking the panels is added.

See also: Laminated glass, PVB and SGP interlayers

Fin

Facade fin

A profile projecting from the facade, vertical or horizontal, for shading or as part of the architectural language. Its depth, spacing and direction follow the facade orientation. A deep fin adds wind load and affects cleaning. Photovoltaic cells can be built into a fin, turning it into a BIPV element that shades the facade and generates electricity. Its direction and angle are then also weighed for yield, and the wiring route is designed with the fin.

Building maintenance unit (BMU)

Facade access system

A permanent installation on the roof with a cradle that travels down the facade for cleaning and maintenance. Alternatives include davit arms, monorails and other solutions. It needs roof space, structural loads and restraint points on the facade, so the decision is made at concept stage.

Louvres

Louvers

Blades, fixed or movable, installed on the facade for shading, ventilation or screening equipment such as condensers and vents. They reduce solar load on the building and add another layer to the facade. Blade angle, spacing and depth follow the facade orientation and the purpose.

Skylight

Roof glazing

Glazing in a roof or ceiling that brings daylight in from above. It is overhead glazing, so it needs laminated glass, careful drainage and sealing, and control of the solar load – which is greater than on a vertical facade.

Finishes

Anodizing

Anodising

An oxide layer formed on the aluminum by an electrochemical process, giving a durable metallic look. Shades can differ between production batches, so an agreed color range is approved in advance on samples.

Powder coating

Polyester powder coating

Powder sprayed onto the profile with an electrostatic charge, then baked in an oven until it melts into an even coat. It is the most common finish for facade aluminum, with a wide range of colors and textures. The quality depends mainly on the pretreatment of the profile before coating and on the powder's UV durability class. Near the sea, a pretreatment suited to marine environments is required. Thickness, gloss level and warranty terms are set in the specification.

PVDF coating

Fluoropolymer coating

A fluorine-based liquid paint, sprayed in two or three coats and baked in an oven. It is highly UV-resistant and keeps its color for years, so it is used on towers, on facades that are hard to maintain and near the sea. The coat stays flexible, so the aluminum can be bent and formed after coating without the paint cracking. Sheets can therefore be coated flat and folded later into cassettes and panels. It costs more than powder coating and offers a narrower range of gloss levels. The warranty depends on the applicator and the distance from the sea, so it too is set in the specification.

Design, tender and construction

Building envelope

Building enclosure

Everything that separates the inside of a building from the outside: curtain walls, windows, cladding, roofs and skylights. The envelope sets the look of the building and its energy use, and takes a large share of the construction budget – so it is worth managing as a project of its own, from design to handover.

Facade consultant

Envelope consultant

The professional who designs and specifies the envelope systems with the architect and follows execution. A consultant or envelope manager acting for the developer checks that the design meets the vision and the budget, runs the contractor tender and supervises execution through handover.

Value engineering

VE

A systematic review of the design to reach the same result – or a better one – at lower cost. In the envelope it may mean changing the glass module, the profile type or the installation method. Good value engineering happens before the tender, while changes are still cheap, and presents cost-tiered alternatives.

Shop drawings

Fabrication drawings

The detailed drawings the envelope contractor prepares before fabrication, based on the architectural design and the specification. They fix the actual profiles, joints, seals and anchors. Reviewing and approving shop drawings is where mistakes are caught before they are manufactured.

Tolerances

Construction tolerances

A concrete frame is built to an accuracy of centimeters, an aluminum facade is made to an accuracy of millimeters. Tolerances set how far each may deviate from the drawings, and how the facade bridges the gap.

The structure's deviations are absorbed by the adjustment range of the anchors and the width of the joints, so these ranges are defined at design stage according to the deviations expected in the structure. Before fabrication the slabs as actually built are surveyed, and the facade is fitted to what exists rather than only to the drawings. A deviation larger than the adjustment range needs a special solution, so the specification sets in advance who surveys and what happens in that case.

A tolerance is not a movement: besides construction deviations, the facade must also absorb the building's movements over its life, such as thermal expansion, slab deflection and sway in the wind.

Mock-up

Performance mock-up

A full-size section of facade built before series production. A visual mock-up lets colors, glass and details be approved in real light; a performance mock-up is tested for water and air tightness and wind loads in a laboratory. It costs money and time, but far less than fixing a finished facade.

See also: PMU, VMU

ift Rosenheim

Institut für Fenstertechnik

A German institute for testing, certification and research on windows, doors, curtain walls and glass, based in Rosenheim, Bavaria. ift stands for Institut für Fenstertechnik, the institute for window technology. It provides accredited tests of air and water tightness, wind load resistance, acoustic and thermal insulation and burglar resistance, including full-size mock-up tests. Aluminum system makers usually present test certificates from ift or another accredited laboratory. In the specification and the tender it is worth checking that a certificate covers the same system, sizes and values the project requires.

PMU

Performance mock-up

A full-size section of the actual facade system, made to the shop drawings and tested in an accredited laboratory such as ift. The test covers air and water tightness and wind load resistance, and building movements where needed. The PMU is tested before series production. If it fails, the details are corrected and it is tested again, and the details that passed bind production. The test schedule, and who bears the cost of a retest, are set in advance in the contract.

VMU

Visual mock-up

A full-size section of facade built on site or at the factory to approve the facade's appearance before production: glass color and reflection, aluminum finish and colors, ceramic frit, joints and lines. It is viewed in daylight and from the distance at which the building will be seen. A VMU does not test performance. Once approved, it serves as the binding benchmark against which the actual work is compared.

U-value

Thermal transmittance

The rate of heat flow through an element, in W/m²K – the lower it is, the better the insulation. It matters to tell the value of the glass alone from that of the whole curtain wall, which includes profiles and spandrels and is always higher. The requirement follows from the energy and green building standards that apply to the project.

Solar heat gain coefficient (SHGC)

g-value, solar factor

The share of solar energy that passes through the glass into the building, as a number from 0 to 1 or a percentage. A low value means less heat and less cooling, but sometimes also less light or a darker tint. In Israel, with its high solar loads, it is one of the key figures in choosing glass.